Reichert ORA G3

The Ocular Response Analyzer® (ORA) G3 is the only device that measures Corneal Hysteresis (CH) and Corneal Compensated IOP (IOPcc). What is Corneal Hysteresis? Corneal Hysteresis has consistently shown to be a more powerful predictor of, and strongly associated with, glaucoma progression, more so than key risk factors such as IOP and CCT. IOPcc is a pressure measurement that is less affected by corneal properties and more associated with glaucoma risk than Goldmann and other tonometers. Ocular Response Analyzer is engineered, designed, and assembled in USA.

Key Features

  • Exclusive Measurements — The only device that measures both Corneal Hysteresis (CH) and Corneal Compensated IOP (IOPcc).
  • Corneal Hysteresis (CH) — A superior, independently validated predictor of glaucoma progression with its own CPT billing code (92145).
  • Corneal Compensated IOP (IOPcc) — A patented measurement that eliminates corneal bias, providing a more accurate true intraocular pressure than Goldmann tonometry.
  • Non-Contact Measurement — Uses an automatic air pulse with no anesthesia, drops, or prism sterilization required, reducing cost and contamination risk.
  • One-Touch Operation — Fully automated alignment and measurement initiated with a single touch, displaying four parameters simultaneously.
  • Advanced Waveform Score — Patent-pending feature that enhances measurement reliability and repeatability.
  • Patient-Friendly Design — No chinrest, customized air pulse per eye, and proven higher patient cooperation rates vs. Goldmann, including in pediatric patients.
  • EMR Integration — Direct patient data export via touchscreen, compatible with ReichertCapture® software.
  • Made in the USA — Engineered and assembled at Reichert’s headquarters in Buffalo, New York.

 

Request a Quote

Description

ADVANCED TONOMETRY

The Reichert Ocular Response Analyzer® (ORA) G3 is the only device that measures Corneal Hysteresis (CH) and Corneal Compensated IOP (IOPcc). What is Corneal Hysteresis? Corneal Hysteresis has consistently shown to be a more powerful predictor of, and strongly associated with, glaucoma progression, more so than key risk factors such as IOP and CCT. IOPcc is a pressure measurement that is less affected by corneal properties and more associated with glaucoma risk than Goldmann and other tonometers. Ocular Response Analyzer is engineered, designed, and assembled in USA.

 

OCULAR RESPONSE ANALYZER® G3 AND CORNEAL HYSTERESIS

Make a more confident glaucoma risk assessment, with Corneal Hysteresis. Only Ocular Response Analyzer® G3 from Reichert® measures Corneal Hysteresis (CH), a superior predictor of glaucoma progression, which is more associated with visual field progression than CCT or IOP.1,3,5 Ocular Response Analyzer helps add clarity to your glaucoma decision making process. CPT Code 92145, was published for the Corneal Hysteresis measurement provided by Ocular Response Analyzer.