Reichert Tono-Pen AVIA

The Tono-Pen AVIA® Tonometer is a precision handheld applanation tonometer designed for fast, reliable intraocular pressure (IOP) measurements across diverse clinical settings. Featuring the innovative Quick-Tap® Measurement Mode and award-winning ergonomic design, it combines calibration-free operation with advanced micro-strain gauge technology to deliver accurate, repeatable results with minimal operator bias.

Key Features

  • Quick-Tap® Dual Measurement Modes: Offers traditional First Generation Mode (typically five taps) and advanced Quick-Tap® Second Generation Mode that provides reliable IOP measurements in as few as two taps—ideal for pediatric and less cooperative patients.
  • Superior Ergonomic Design: Features an award-winning, lightweight construction with soft-touch grips that fits comfortably in any hand, ensuring consistent measurement technique and making it equally suitable for left or right-handed operators.
  • Advanced Measurement Technology: Utilizes micro-strain gauge technology that is less sensitive to corneal centration than other tonometers, delivering fast, accurate, and repeatable results with reduced operator bias and minimal training requirements.
  • Effortless Operation: Simple one-button operation with intuitive visual feedback—green light indicates ready-to-measure status, audible beep confirms measurement completion, and dual-sided LCD screens display results clearly for ambidextrous use.
  • Ultimate Versatility: Gravity-independent design allows measurements in any position, making it ideal for patients confined to wheelchairs or beds, with statistical confidence indicators providing real-time measurement reliability feedback.
  • Ready-to-Use Reliability: Calibration-free operation ensures the device is always ready for clinical use, with a long-life removable POWERCEL® battery pack providing thousands of measurements and tool-free replacement via simple squeeze-and-pull mechanism, plus convenient on-screen battery monitoring.

 

Request a Quote

Description

FEATURING QUICK-TAP® MEASUREMENT MODE

Tono-Pen AVIA® Tonometer, now with Quick-Tap® Measurement Mode… More confidence in fewer measurements. Tono-Pen AVIA® Tonometer is always ready-to-use and calibration-free. An award-winning ergonomic design, long life battery good for thousands of measurements, statistical confidence indicator, and now Quick-Tap Measurement Mode, make it the most advanced Tono-Pen® Tonometer yet. The one you trust in tonometry. Designed & assembled in USA.

Tono-Pen AVIA Tonometer, like the Tono-Pen XL Tonometer, uses sanitized Ocu-Film® + Tip Covers to minimize the risk of patient cross contamination.

Tono-Pen® Tonometer and Ocu-Film® + Tip Cover products are also available from your Authorized Reichert Technologies Distributor. Add them to a Quote Request to contact a distributor near you. For US government sales, please call 1-888-849-8955 to place your order.

TONO-PEN AVIA® TONOMETER, MEASURE QUICKLY & CONFIDENTLY

Tono-Pen AVIA® Tonometer with Quick-Tap® Measurement Mode builds on all the features that made the classic Tono-Pen® XL Tonometer the most widely used handheld tonometer. Tono-Pen AVIA requires no calibration and is always ready-to-use, has an award-winning ergonomic design, longer battery life, and an enhanced IOP averaging technique with two measurement modes. This makes it the most advanced Tono-Pen yet!

 

NOW AVAILABLE WITH QUICK-TAP® MEASUREMENT MODE

Select from one of two measurement modes; the traditional First Generation Mode, which provides an IOP measurement typically in five taps, and now the Quick-Tap® Second Generation Measurement Mode where you can obtain a reliable IOP measurement in as few as two taps. This is especially useful for children and less cooperative patients.

 

TONO-PEN AVIA®, INNOVATIVE AND THOUGHTFULLY DESIGNED

  • No Calibration Required
    • Routine calibration of Tono-Pen AVIA Tonometer is not required. Spend less time worrying about your instruments and more time with your patients.
  • Award Winning Ergonomic Design
    • With its award-winning, ergonomic design and soft-touch grips, the lightweight Tono-Pen AVIA Tonometer fits comfortably in any operator’s hand, ensuring consistent measurement technique among users.
  • Simple One Button Operation
    • To take a measurement, simply press the button once. When the light turns to green, Tono-Pen AVIA Tonometer is ready to use. Gently tap the anesthetized cornea until a short beep sounds to alert the operator that the measurement is complete.
  • Less Sensitive to Corneal Centration
    • Using micro-strain gauge technology, Tono-Pen AVIA Tonometer is less sensitive to corneal centration than other tonometers and provides fast, accurate, and repeatable results with minimal operator bias.
  • Technician Friendly
    • Simple one button operation, award winning ergonomics, less sensitivity to corneal centration, and statistical confidence indicator makes delegation of Tono-Pen AVIA Tonometer to an eye care technician easy and worry-free. Only minimal training is necessary to become proficient in obtaining reliable IOP measurements.
  • Gravity Independent
    • Unlike most other tonometers, Tono-Pen AVIA Tonometer can be used in any position, making it easy to measure all patients, including those who may be confined to a wheelchair or bed.
  • Large Dual Sided Screens
    • The IOP measurement is displayed on two large, easy-to-read, LCD screens making it suitable for both left and right handed users.
  • Long-life Battery
    • The convenient on-screen battery indicator ensures that Tono-Pen AVIA Tonometer will always be ready for use. The removable Tono-Pen AVIA POWERCEL® battery pack is easily replaced, requiring no tools. Just squeeze and pull.

 

DESIGNED & ASSEMBLED IN THE USA

Tono-Pen tonometers are proudly designed and assembled in our state-of-the art world headquarters in Buffalo, NY, USA.